field_stop_vertices#
- esis.flights.f1.optics.field_stop_vertices(path=None)[source]#
Load the measured vertices of the ESIS-I field stop.
The field stop is a regular octagon by design, but its image in the four channels is not: its sides tilt by up to a degree and move by a few microns, and the four channels, each through its own grating and sensor, agree on that shape to a few hundredths of a degree and half a micron. The vertices are measured from the median edges of the O V window over the flight by
esis.flights.f1.optics.measure_field_stop(), carried back to the plane of the stop through the distortion fit, with each channel’s own rotation, shift and scale removed and the stop’s rotation left to theroll_field_stopof the fit.